THE MOORE 06 FEED LINE CONTROL – MORE THAN JUST A FEED LINE SWITCH!
The Moore 06 Feed Line Control is more than just a single feed line switch. The control has capabilities as a consumption meter and cycle timer and can be used in a flag feed system
SETTING YOUR CONTROLS IS SIMPLE
Run Delay (Hours)
Press and hold the down arrow key for 5 seconds, – – – will appear followed by a display of the present setting with the cursor flashing fast. To set the time, press the up or down arrow keys to achieve the desired time delay. Note: All settings below 1 hour are in tenths of an hour; refer to the chart for settings. After the desired time delay is set, wait 5 seconds. When the cursor flashes slow the new time will be accepted. The unit will now go into Run Delay. Wait for this time to expire or turn the power off then back on for immediate start.
Max Run Time (Minutes)
Press and hold the up arrow key for 5 seconds,- – – will appear followed by a display of the present setting with the cursor flashing fast. To set the time, press the up or down arrow keys to achieve the desired time. Note: these are in minutes and tenths of minutes. After the desired time is set wait 5 seconds. When the cursor flashes slow the new time will be accepted. The unit will now go into Run Delay. Wait for this time to expire or turn the unit off then back on for immediate start.
Consumption Meter
Another feature of the MOORE 06 is its ability to record the total amount of auger run time (in hours and minutes) for the past 24 hours. Press and hold both switches to display this value. The run time total is updated on a minute-to-minute basis.
THE MOORE 06 FEED LINE CONTROL – MORE THAN JUST A FEED LINE SWITCH!
- Consumption Meter
- Cycle Timer
- Flag Feed System Control